Strona 1 - VisualServer

VisualServer VS3102 User's Manual

Strona 2 - Before You Use

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 9Rear Panel Ethernet 10/100 socket Connect to Ethernet network with a UTP c

Strona 3 - Table of Contents

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 10General I/O terminal block 1 Å DI+ INPUT (Max. 50mA,

Strona 4

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 11Status LEDs Each time VisualServer starts, it will perform a Power-On Sel

Strona 5

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 12Restore button There is a button hidden in the box for restoring the syste

Strona 6

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 13How to Install To easily fit into various environments, VisualServer automa

Strona 7 - Package Contents

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 14Ethernet Environment Hardware installation Before installing multiple Visua

Strona 8

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 15Power on Make sure all cables are correctly and firmly connected before tur

Strona 9 - Physical Description

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 16Software configuration Easy way with installer program In order to configur

Strona 10 - Rear Panel

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 17The IP address shown in "Current IP Address" field is for the adm

Strona 11 - General I/O terminal block

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 18When IP and options are O.K., click on . A message window will pop open to

Strona 12 - Status LEDs

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 1Before You Use Surveillance devices may be prohibited by law in your country

Strona 13 - Power adapter

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 19After successful notification, administrators may keep the address informat

Strona 14 - How to Install

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 20While checking “Use this IP whenever system boots”, a dialog window may pop

Strona 15 - Ethernet Environment

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 21Manual way with existing programs In addition to the provided installer pro

Strona 16 - Power on

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 22First access to VisualServer When connecting to VisualServer for the first

Strona 17 - Software configuration

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 23the previous settings. If the install option stays checked, VisualServer wi

Strona 18

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 24Modem Environment Hardware installation Before installing VisualServer, the

Strona 19

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 25Cable connection Shut down the peripheral devices prior to connection. Con

Strona 20

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 26Software configuration For the first time, users should connect the include

Strona 21

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 27Check "Don't detect my modem..." item and click on to

Strona 22

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 28Choose the serial port that the included null modem cable is attached to an

Strona 23 - First access to VisualServer

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 2Table of Contents Before You Use...

Strona 24

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 29Setup a new connection After the 33600 bps modem is installed, open the di

Strona 25 - Modem Environment

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 30Just enter arbitrary digits as phone number and click on . The phone numbe

Strona 26 - Cable connection

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 31Right-click on the newly setup connection icon for properties. In the f

Strona 27

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 32Select 115200 as the speed and click on . On the second page, only chec

Strona 28

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 33Double click the newly setup connection. A dialing information window will

Strona 29

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 34First access to VisualServer Through direct connection by null modem cable

Strona 30 - Setup a new connection

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 35basic configurations. If people other than the administrator will be allowe

Strona 31

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 36How to Use VisualServer is a well-designed stand-alone video server. With t

Strona 32

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 37Authentication After opening the Web browser and typing in the URL of Visua

Strona 33

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 38If it is initial access to VisualServer in Windows, the web browser will as

Strona 34

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 3Hardware installation...

Strona 35

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 39Primary user’s capability Main screen with camera view There is a logo imag

Strona 36

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 40PTZ camera control A PTZ motorized camera is provided by customers and shou

Strona 37 - How to Use

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 41Client Setting If it is the first access to “Client Setting” page in Window

Strona 38 - Authentication

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 42real-time issue is worse than UDP protocol. If your environment is behind t

Strona 39

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 43System configuration There are two methods provided for configuration. Web

Strona 40 - Primary user’s capability

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 44System parameters To change the system name, type in the text box after &

Strona 41 - PTZ camera control

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 45 When user sets the illegal range of Date or Time, server will not accept

Strona 42 - Client Setting

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 46User group administration To change the administrator’s password, type th

Strona 43

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 47Network settings Any change made to this page will make the system restar

Strona 44 - System configuration

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 48option is ignored in the PPP connection. Administrators may modify the net

Strona 45 - System parameters

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 4FTP Uploading snapshots periodically to an external FTP server ...

Strona 46

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 49 If the VisualServer works in variation or low bandwidth (comparing with vi

Strona 47 - User group administration

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 50modem for software installation.

Strona 48 - Network settings

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 51Video codec parameters Options on this page will affect the image on the

Strona 49

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 52VS3102 uses MPEG4 codec compression for best streaming solution. The compre

Strona 50

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 53 To adjust image settings for best visual quality, press and a motion pi

Strona 51

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 54Motion detection Please note that the option "Enable Motion Detectio

Strona 52 - Video codec parameters

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 55The following figure shows the screen when is clicked. The monitoring wi

Strona 53

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 56PTZ camera configuration Since VisualServer can be used in either Etherne

Strona 54

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 57VisualServer can support any other custom camera by selecting "Custom

Strona 55 - Motion detection

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 58 VisualServer provides five more custom commands other than general pan, t

Strona 56

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 5Security configuration URL ...

Strona 57 - PTZ camera configuration

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 59 If the attached motorized camera is not on the support driver list, choos

Strona 58

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 60When everything is set, click on to save the commands and click on to

Strona 59

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 61Modem and dialup settings In PPP interface, a modem option will work inst

Strona 60

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 62minutes" will force VisualServer to drop the connection when there is

Strona 61

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 63Application Administrators can use combinations of options on the applica

Strona 62 - Modem and dialup settings

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 64 The other "Event operation" can be used to combine motion detect

Strona 63

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 65Homepage layout settings Administrators may give VisualServer a different

Strona 64 - Application

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 66One-shot fast configuration via FTP For quick setup of VisualServer, the ad

Strona 65

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 670002D1000001 Read only string <software version> IP2001-1A-VVTK-0

Strona 66 - Homepage layout settings

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 68<user password> (0) 0002D1000001 Initial value is as same as seria

Strona 67

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 6Package Contents VisualServer VS3102 Power adapter Camera control cable

Strona 68

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 69<logo type> 1 0 for blank, 1 for default image or 2 for loading

Strona 69

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 70<primary name server> 192.168.0.1 Standard IP format <secondar

Strona 70

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 71<backup ftp password> String shorter than 15 characters <ba

Strona 71

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 72<saturation> 0 among 5 and -5 <rate control> YES fo

Strona 72

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 73Canon VCC3, Dynacolor Dome and Pelco Camera <uart mode> RS232 or

Strona 73

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 74<application mode> 0 for none, 1 for sequential mode, 8 for eve

Strona 74

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 75Advanced functions Web Viewing system log Click the button on the configura

Strona 75

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 76FTP VisualServer not only has web service for easy access but also has a bu

Strona 76 - Advanced functions

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 77Viewing system log Download SYSTEM.LOG and open it with any text viewer. Th

Strona 77 - Customizing homepage images

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 78the “Reset network at next boot” option is enabled or not. After VisualServ

Strona 78 - Software revision upgrade

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 7 I/O terminal block connector Wrench Installation and document CD Quic

Strona 79

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 79Telnet VisualServer has a Telnet daemon for administrators to access some s

Strona 80

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 80 Set digital outputs To set digital output to connect NO with COMMON, type

Strona 81

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 81URL commands of VisualServer For some customers who already have their own

Strona 82 - URL commands of VisualServer

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 82Clear data mode serial port driver This URL applies to the attached serial

Strona 83 - Restart system

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 83Page URL The configuration page has a frame layout including an option list

Strona 84 - Page URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 84System resource URL There are some images used on the homepage when the hom

Strona 85 - System configuration URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 85Security configuration URL URL: /setup/security.cgi NAME VALUE DESCRIPTION

Strona 86 - Network configuration URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 86ftp1 <domain name or IP address> primary FTP server ftpuser1 <t

Strona 87 - Video configuration URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 87768000 set bit rate to 768K bps 1000000 set bit rate to 1000K bps 120000

Strona 88

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 88restore <not required> recall the original settings save <not r

Strona 89 - Camera configuration URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 8Physical Description Front Panel BNC video input 75Ohms resistance video p

Strona 90 - Modem configuration URL

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 89str5 <text string shorter than 8 characters> button name of custom

Strona 91

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 90Tone (ATDT) make modem dial in tone method Pulse (ATDP) make modem dial i

Strona 92

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 91mdalarm < not required > trigger DO when motion detected ioupload

Strona 93 - Appendix

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 92 Appendix A. POST procedure After the power has been turned on, VisualServ

Strona 94

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 93B. Frequently asked questions Q. What if I forget my password? A. Every acc

Strona 95

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 94from modem property in the control panel. While in Ethernet, it may be due

Strona 96

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 95Q. I have a PTZ camera that is not on the supported list. How can I control

Strona 97 - C. Technical specifications

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 96C. Technical specifications Remote Management Configuration and system log

Strona 98 - Liability

www.vivotek.com T: 886-2-22404099 F: 886-2-22404097 97Electromagnetic Compatibility (EMC) USA - This equipment has been tested an

Komentarze do niniejszej Instrukcji

Brak uwag

Eaton FerrUPS FE manuály

Uživatelské manuály a uživatelské příručky pro Nepřerušitelné zdroje napájení (UPS) Eaton FerrUPS FE.
Poskytujeme 3 manuály pdf Eaton FerrUPS FE ke stažení zdarma podle typů dokumentů: Instalační příručka, Uživatelský manuál


Tabulka s obsahem

Eaton FERRUPS

1

Rack Mount UPS

1

Installation Guide

1

Class A EMC Statements

2

Table of Contents

3

TABLE OF CONTENTS

4

Chapter 1 Introduction

5

INTRODUCTION

6

Chapter 2 Safety Warnings

7

VIGTIGE SIKKERHEDSANVISNINGER

8

GEM DISSE ANVISNINGER

8

BEWAAR DEZE INSTRUCTIES

9

TÄRKEITÄ TURVAOHJEITA - SUOMI

10

SÄILYTÄ NÄMÄ OHJEET

10

CONSERVER CES INSTRUCTIONS

11

AUFBEWAREN

12

   

13

CONSERVARE QUESTE ISTRUZIONI

14

GJEM DISSE INSTRUKSJONENE

15

GUARDE ESTAS INSTRUÇÕES

16

SAFETY WARNINGS

17

GUARDE ESTAS INSTRUCCIONES

18

VIKTIGA SÄKERHETSFÖRESKRIFTER

19

SPARA DESSA FÖRESKRIFTER

19

V I K T I G T

20

Chapter 3 Setup

21

S 164201425 Rev 1

22

Location Requirements

23

-20° to 60°C (-4° to

24

W A R N I N G

25

C A U T I O N

25

A U T I O N

26

Electrical

27

Identifying the Batteries

28

BATTERY CABINET INSTALLATION

29

Figure 6. Frame Assembly

32

Tab (Front End)

33

U-shaped Brackets

34

Table 7. Battery Torque Value

36

-) terminals

37

RBC-3 Battery Cabinet Parts

38

Rear Panel

39

Knockouts

39

Inner Rail

39

Outer Rail

39

Figure 19. RBC-3 DC Switch

43

+) and negative (-)]

44

Terminal Strip

45

UPS CABINET INSTALLATION

48

Bypass Switches

53

ELECTRICAL INSTALLATION

54

A R N I N G

55

Follow local

58

GROUNDING

63

ELECTRODE

63

TERMINAL

63

Charger 4.3 kVA 7 kVA

68

Standard 40A 70A

68

10A 45A 70A

68

Standard 25A 40A

69

10A 25A 40A

69

Chapter 7 Battery Wiring

73

RBC-1 or RBC-2 DC Wiring

74

BATTERY WIRING

75

RBC-3 DC Wiring

76

Replacing the Batteries

76

Recycling the Used Battery

78

Chapter 8 Phase Check

79

PHASE CHECK

81

*1642014251*

84





Další produkty a příručky pro Nepřerušitelné zdroje napájení (UPS) Eaton

Modely Typ Dokumentu
Powerware Series Manuál s instrukcemi   Eaton Powerware Series Instruction manual, 108 stránky
5130 Uživatelský manuál   Eaton 5130 UPS, 7 stránky
5115 Uživatelská příručka    Eaton 5115 User`s guide, 66 stránky
9E Generation 3 Provozní pokyny   Eaton 9E Generation 3 Operating instructions, 116 stránky
Powerware 9355 Uživatelská příručka   Eaton Powerware 9355 User`s guide, 50 stránky
5P 1500 RT Uživatelský manuál   Eaton 5P Tower UPS - CL, 28 stránky
Evolution 850 Rack 1U Uživatelský manuál   Eaton Evolution 850 Rack 1U User manual [de] [en] , 22 stránky
825 UPS Provozní pokyny   Eaton 825 UPS Operating instructions, 262 stránky
550 Uživatelský manuál    Eaton 550 User manual, 6 stránky
5P 1500 RT Uživatelský manuál   Eaton 5P 1500 RT User manual, 129 stránky
UPS 20 Manuál s instrukcemi   Eaton UPS 20 Instruction manual, 238 stránky
Powerware 9355 Parallel Uživatelská příručka   Eaton Powerware 9355 Parallel User`s guide [en] , 82 stránky
Powerware BladeUPS Bar Uživatelská příručka    Eaton Powerware BladeUPS Bar User`s guide, 134 stránky
Powerware 9910 EBM Uživatelský manuál   Powerware 9910 pSeries UPS Solutions, 6 stránky
Powerware 9170+ UPS 3-18 kVA Uživatelská příručka   Eaton Powerware 9170+ UPS 3-18 kVA User`s guide, 94 stránky
Pulsar Series Uživatelský manuál     Eaton Pulsar Series User manual, 120 stránky
Powerware 9355 Parallel Instalační příručka    Eaton Powerware 9355 Parallel Installation guide, 40 stránky
9135 Uživatelský manuál   Eaton 9135 UPS, 4 stránky
Eaton 9140 Uživatelská příručka    Eaton Eaton 9140 User`s guide, 42 stránky
EX 1500 RT 2U Uživatelský manuál   Eaton EX 1500 RT2U Marine, 1 stránky